Texas calls a septic system and its drain field an on-site sewage facility (OSSF). Chapter 366 of the Health and Safety Code is the governing statute, and the Texas Commission on Environmental Quality (TCEQ) writes the working rules in 30 TAC Chapter 285. Section 366.051(b) settles who issues a permit: the authorized agent where the system sits within an agent's jurisdiction, and the commission otherwise. TCEQ's permit page says its regional office permits where no local jurisdiction has been authorized.

An authorized agent, as 30 TAC 285.2 defines it, is a local governmental entity (a municipality, county, river authority or special district, such as a public health district) to which the executive director has delegated the OSSF program. Under section 366.032 a local order or resolution must incorporate the commission's rules on preventing pollution and injury to public health, meet its minimum requirements and include a written enforcement plan, and where it adopts more stringent standards that give greater public health and safety protection, it prevails over the state chapter and standards.

Under the definitions in Rule 285.2, swapping out any OSSF component is a repair unless it falls under the emergency repairs of 285.35 or is maintenance, and a new tank or drainfield counts as a repair that brings a permit for the whole OSSF, not only the part being replaced.

Texas Service Details

What providers in this area actually see: coverage, common jobs, local pricing factors, and rules worth knowing.

Service Area Notes

  • Finding the office: TCEQ's OARS directory lists authorized agents by county and explains what to check when a county returns more than one listing.
  • McLennan County: OARS shows McLennan County as authorized agent for the entire county. Local details are on the McLennan County page.
  • Bell County: OARS shows the Bell County Public Health District as authorized agent for the entire county. Its local rules and fees are on the Bell County page.
  • For any other Texas county, search OARS. Cornelia Cove LLC does not issue permits or speak for TCEQ or any authorized agent.

Common Jobs in Texas

  • Replacing a failed drainfield, a repair under Rule 285.2
  • Rebuilding with a nonstandard design such as a low-pressure dosed drainfield; under 285.33(d), planning materials for any disposal system not described or defined in subsections (b) and (c) of that rule must be developed by a professional engineer or professional sanitarian
  • Emergency repairs within 285.35, such as new tank lids or inlet and outlet devices, riser and riser-cap repairs, disinfection device repair or replacement, and fixes to damaged drip tubing or solid lines (conditions in the emergency section below)
  • Closing boreholes, cesspools or seepage pits, which 285.3(i) bars from installation or use; those treating or disposing of less than 5,000 gallons of sewage per day close under 285.36, and larger ones as Class V injection wells

What Drives Pricing Here

  • What the ground shows: under 285.30, a site evaluator or professional engineer examines the soil in two borings or two backhoe pits placed at opposite ends of the planned disposal area (the permitting authority may ask for more where soils are highly variable), sorts the soil into classes running from Ia (sandy soils with more than 30% gravel) to IV (silty clay and clay), checks for restrictive horizons and for signs of groundwater within 24 inches of the excavation bottom, and maps slopes, the 100-year floodplain and separation distances. The rule says that information is used to determine the type and size of the OSSF.
  • Paperwork tied to the system type: for the OSSFs listed in Table XII of 285.91(12), 285.3(b)(3) requires the owner or the owner's agent, before an authorization to construct is issued, to record an affidavit in the deed records of the county or counties where the OSSF is located and to submit to the permitting authority an affidavit affirming the recording. The recorded affidavit must include the owner's full name; the legal description of the property; that an OSSF requiring continuous maintenance is located on the property; that the OSSF permit is transferred to the new owner upon transfer of the property; and that at any time after the initial two-year service policy, the owner of an aerobic treatment system for a single family residence shall either obtain a maintenance contract within 30 days of the transfer or maintain the system personally. The rule points to an example affidavit in 285.90(2). The same table drives the maintenance contract, testing and reporting duties of 285.7.
  • Fees: the permit fee is paid to whichever of the authorized agent or the commission performs the permitting (section 366.059(a)), and section 367.010 adds a $10 fee for each on-site wastewater treatment permit application processed, which local collectors forward to the commission. Under 285.3(d)(5)-(6), a reinspection fee may be assessed and must be paid before the reinspection. Local permit amounts are on the county pages.

Permits & Local Rules

  • Permit and plan: section 366.051(a) and 30 TAC 285.3(a) make a permit plus an approved plan the precondition for building, altering, repairing, extending or operating an OSSF, with the rule's exceptions collected in 285.3(f).
  • Older systems: 285.3(f)(1) excuses an owner from the chapter's permitting, operation and installation requirements when the OSSF is not creating a nuisance and it either was installed before September 1, 1989, or was installed before the effective date of a local order dated before that day, and in both cases has not been altered and is not in need of repair; or the owner received an authorization to construct before the chapter's effective date. TCEQ's permit page tells owners of "grandfathered" systems to confirm with the local permitting authority.
  • Applying: 285.3(b)(1) requires an authorization to construct before construction begins, which the authority issues once the owner or agent has filed its application form together with 285.5 planning materials, the 285.30 site evaluation results and the fee. Under 285.3(c) the authority approves or denies within 30 days of receiving the application and explains a denial in writing.
  • Building it: under 285.3(d), an authorization to construct is valid for one calendar year; if the installer has not requested a construction inspection within that year it expires, and the owner has to file a new application and fee before installing (nothing new is owed if the owner drops the installation). The installer must alert the authority no fewer than five working days, counted Monday through Friday without holidays, before the system is ready to be inspected, and a system that fails the construction inspection cannot be used until it passes.
  • Licenses: section 366.071(a) requires anyone who constructs, installs, alters, extends, services, maintains or repairs an OSSF or any part of one for compensation to hold a TCEQ license or registration, and subsection (c) requires a TCEQ license for preconstruction site evaluations unless the person is a licensed professional engineer. TCEQ's licensing page says an Installer I may install standard systems (septic tanks, absorptive drainfields, unlined ET drainfields, leaching chambers, gravel-less pipe and pumped effluent drainfields) and an Installer II may install all types.
  • Maintenance licenses: under 285.7(b)(1), maintenance on an OSSF is done by a TCEQ-licensed maintenance provider or by a registered maintenance technician employed by one; owners who maintain their own systems are covered in the FAQs.

Local Conditions

  • Clay: NRCS's Texas soils page names Houston Black the state soil, saying it "developed from calcareous clays and marls" laid down in the Cretaceous and is "sticky and moldable when wet," which is why it is "often called 'black gumbo.'" Rule 285.30 places clay and silty clay in Soil Class IV and counts clay subsoils, rock and plugged laminar soils as restrictive horizons.
  • Groundwater: the Texas Water Development Board recognizes 9 major and 22 minor aquifers. Its aquifer page says an aquifer's outcrop is its principal recharge zone and that groundwater there is "normally under unconfined, water-table conditions and is most susceptible to contamination."
  • Edwards Aquifer: for property on the Edwards Aquifer recharge zone, 285.4(a) points to the additional requirements of 285.40.

Neighborhoods & Suburbs Served

McLennan County · Bell County · Waco · Killeen · Temple

Cross-section of one drain field trench under a lawn. Below a soil cover and a barrier fabric, a perforated pipe with its holes facing down lies in a bed of gravel. Effluent drips out of the pipe, spreads through the gravel and soaks into the soil, where a thin biomat layer forms along the trench bottom and walls. Beneath the trench, a band of unsaturated soil finishes treating the effluent above the seasonal high water table.
The soil under the trench does the final treatment, so local soil type and water-table depth decide how big the field must be or whether it needs an engineered design.

Emergency Response Expectations

Section 366.017(b) of the Health and Safety Code says the property owner must take adequate measures as soon as practicable to abate an immediate health hazard. Under 30 TAC 285.35, an emergency repair is allowed when two tests are met (it abates "an immediate, serious and dangerous health hazard" and it is not an alteration of the system's planning materials and function), and the work must meet the chapter's criteria. Within 72 hours after the work starts, whoever is authorized to make the repair must send the permitting authority written notice that describes in detail the methods and materials used, and the authority may decide to inspect. Replacing the field itself is a repair that needs a permit, so find the permitting authority through TCEQ's OARS directory before that work starts.

Texas FAQs

Can I replace the drain field on my own home without a licensed installer?

30 TAC 30.244(a)(1) lets a person who, in an individual capacity, owns a single-family dwelling install or repair an OSSF on that property without an installer license, but not on property to be developed for sale or lease. The owner must meet all of the permitting authority's permitting, construction and maintenance requirements; anyone the owner pays to construct any portion must be a licensed installer; and the site evaluation must be done by someone holding a current site evaluator or professional engineer license. Paragraph (a)(2) gives a parallel exemption to the owner of a single-family dwelling served by an aerobic system, with the same permitting, paid-labor and sale-or-lease limits. Subsection (b) separately lets a licensed electrician install the electrical components, and a person delivering a treatment or pump tank set it in the excavation, without an installer license. TCEQ's permit page adds that whether an owner may do this depends on whether the local permitting authority allows it.

Does a tract of ten acres or more still need a permit?

Under 30 TAC 285.3(f)(2), a single family dwelling's OSSF on ten or more acres is exempt from planning materials, permits and inspections when it satisfies every other Subchapter D requirement and four conditions hold: no nuisance or groundwater pollution, no part of it closer than 100 feet to a property line, all effluent kept on the property, and no other dwelling on the tract. TCEQ's permit page lists a site evaluation by a licensed site evaluator or professional engineer among the conditions and notes that local programs can be more stringent, so confirm with the authorized agent first.

After a notice that my system is malfunctioning, when does repair have to begin?

30 TAC 285.70(a) has the owner initiate repair by the 30th day after the notice from the executive director or authorized agent when the owner had no earlier malfunction notice in the prior 12 months, by the 20th day if there was at least one such notice, and by the 10th day if there were at least two. Section 366.017(a) of the statute frames the same 30/20/10-day marks as dates by which the agency may require the repair, and subsection (c) allows a penalty for each day the system remains unrepaired. Ask the permitting authority which date its notice sets.

Does an aerobic system need a maintenance contract after a field replacement?

Rule 285.7 ties contract, testing and reporting duties to the system types in Table XII of 285.91(12). For a single family residence, 285.7(d)(4) lets the owner maintain the system personally or get a new contract once the initial two-year service policy ends (if the home sells before then, the policy's terms apply to the new owner), but not for commercial, speculative residential or multifamily property; and 30 TAC 30.244(a)(3) says an owner who elects to maintain an aerobic system need not register as a maintenance provider but must follow Chapter 285. In a county of at least 40,000 people, 285.70(b) lets the authorized agent or the commission require a homeowner who maintains an aerobic system for a single-family residence to contract for maintenance if the owner does not correct a violation by the 10th day after receiving notice of it, or commits another violation before the third anniversary of the first.